Phase I oncology trials aim to identify a safe dose—often the maximum tolerated dose (MTD)—for subsequent studies. Conventional designs focus on population-level toxicity modeling, with recent attention on leveraging pharmacokinetic (PK) data to improve dose selection. We propose the Precision Dose-Finding (PDF) design, a novel Bayesian phase I framework that integrates individual patient PK profiles into the dose-finding process. By incorporating patient-specific PK parameters (such as volume of distribution ${V_{i}}$ and elimination rate ${k_{i}}$), PDF models toxicity risk at the individual level, in contrast to traditional methods that ignore inter-patient variability. The trial is structured in two stages: an initial training stage to update model parameters using cohort-based dose escalation, and a subsequent test stage in which doses for new patients are chosen based on each patient’s own PK-predicted toxicity probability. This two-stage approach enables truly personalized dose assignment while maintaining rigorous safety oversight. Extensive simulation studies demonstrate the feasibility of PDF and suggest that it provides improved safety and dosing precision relative to the continual reassessment method (CRM). The PDF design thus offers a refined dose-finding strategy that tailors the MTD to individual patients, aligning phase I trials with the ideals of precision medicine.
We consider a formal statistical design that allows simultaneous enrollment of a main cohort and a backfill cohort of patients in a dose-finding trial. The goal is to accumulate more information at various doses to facilitate dose optimization. The proposed design, called Bi3+3, combines the simple dose-escalation algorithm in the i3+3 design and a model-based inference under the framework of probability of decisions (POD), both previously published. As a result, Bi3+3 provides a simple algorithm for backfilling patients to lower doses in a dose-finding trial once these doses exhibit safety profile in patients. The POD framework allows dosing decisions to be made when some backfill patients are still being followed with incomplete toxicity outcomes, thereby potentially expediting the clinical trial. At the end of the trial, Bi3+3 uses both toxicity and efficacy outcomes to estimate an optimal biological dose (OBD). The proposed inference is based on a dose-response model that takes into account either a monotone or plateau dose-efficacy relationship, which are frequently encountered in modern oncology drug development. Simulation studies show promising operating characteristics of the Bi3+3 design in comparison to existing designs.